Vmux-210 Ver. 1.1 Configuring for Operation 4-17
Table 4-16. Ringer Profiles Parameters
Parameter Description Possible Values/
Reference
Profile Number Selected profile to display/configure Profile #1
Profile #2
Default: Profile #1
Period #1: Ring
(100 m
Sec)
Duration of the ring tone; when using a
double ring tone, this is the duration of the
first half of the ring tone
1..50
Default: 10
Period #1: Silence
(100 m
Sec)
Length of the silence period after the first
ring tone; for locations that have only a
single ring tone, this is the period of silence
between rings; for locations that have a
double ring tone, this is the period of silence
between the two ring tones
1..50
Default: 30
Period #2: Ring
(100 mSec)
Duration of the second ring tone 0..50
Default: 0
Period #2: Silence
(100 m
Sec)
Length of the silence between each set of
double ring tones
0..50
Default: 0
Profile #2 is only used when the Ring II signaling bits received from the network
are different than the Off Hook and Ring I bits. For more information, see
Configuring a Bundle’s Signaling Bits on page 4-30.
Configuring Gains
To configure the Gains:
From the Main Menu, select Configuration > Physical Ports > Analog > Gains.
Gains
1. Channel Number[1 - 30]... (1)
2. Tx Gain (db)> (0)
3. Rx Gain (db)> (0)
Figure 4-17. Gains Menu