Installation and Operation Manual Chapter 4 Configuration
Vmux-210 Ver. 1.1 Configuring for Operation 4-53
Table 4-53. Edit NAT Parameters for Single NAT Type
Parameter Description Possible Values/
Reference
NAT Number Number of NAT to be modified 1..5
Default: 1
NAT Type Type of NAT Single
Static
Dynamic
Transparent
Interface Interface on which this NAT is defined
Notes:
Uplink Port is only available when uplink
is not Ethernet.
User Port is only available when Ethernet
Net/User Connection is defined as
Layer 3 Routing.
Net Eth Port
User Eth Port
Uplink Port
Real IP Real IP address of this NAT
Note: Only available for Single and Static
NAT Type.
Real Highest IP Highest real IP address of this NAT
Note: Only available for Dynamic and
Transparent NAT Type.
Real Lowest IP Lowest real IP address of this NAT
Note: Only available for Dynamic and
Transparent NAT Type.
Virtual IP Virtual IP for this NAT
Note: Only available for Static
NAT Type.
Virtual Lowest IP Lowest virtual IP for this NAT
Note: Only available for Single and Dynamic
NAT Type.
Virtual Highest IP Highest virtual IP for this NAT
Note: Only available for Single and Dynamic
NAT Type.
Static PAT Table Opens the Static PAT Table
Note: Only available for Single NAT Type.
See
Table 4-54
Configuring the Static PAT Table
Use the Static PAT Table to configure translations for a specific range of ports
that must remain unchanged.