RAD Data comm Vmux-210 Specifications Page 162

  • Download
  • Add to my manuals
  • Print
  • Page
    / 192
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 161
Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual
6-20 Testing Vmux-210 Vmux-210 Ver. 1.1
Remote Loopbacks on an Analog Channel
To perform a remote loopback on an Analog channel:
1. From the Main Menu, select Diagnostics > Analog > Remote Loop Test.
The Remote Loop Test menu appears (see
Figure 6-15
).
2. Select the desired port, and then select Activate.
Remote Loop Test
1. Channel[1 - 30] ... (1)
2. Activate>
Figure 6-16. Remote Loop Test Menu for Analog Channels
Table 6-10. Remote Loop Test Parameters
Parameter Description Possible Values/
Reference
Channel Selected channel for test 1..30
Activate Activates the loopback test
Remote Loopbacks on an E1/T1 Uplink
To perform a remote loopback on an E1/T1 Uplink:
From the Main Menu, select Diagnostics > E1/T1 Uplink > Remote Loop Test >
Activate.
Pinging Remote Devices
The ping utility is used to confirm IP connectivity by pinging other IP hosts. The
connectivity is confirmed be receiving a reply from the remote (pinged) hosts.
To ping a host:
1. From the Main Menu, select Diagnostics > Ping.
2. Configure the desired parameters, according to
Table 6-11
, and then select
Activate.
Ping
1. IP Address... (0.0.0.0)
2. Number Of Pings[1 - 10]... (1)
3. Send
Figure 6-17. Ping Menu
Page view 161
1 2 ... 157 158 159 160 161 162 163 164 165 166 167 ... 191 192

Comments to this Manuals