Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual
6-18 Testing Vmux-210 Vmux-210 Ver. 1.1
Vmux-210
Phone/Key System
Testing Equipment
~
Analog
Interface
A/D
Converter
Figure 6-11. Local Tone Injection on the Voice Ports
Uplink
Analog
Interface
Analog
Interface
A/D
Converter
A/D
Converter
Testing
Equipment
Uplink
Local Vmux-210Remote Vmux-210
Figure 6-12. Remote Tone Injection on the Voice Ports
To activate tone injection:
1. From the Main Menu, select Diagnostics > Analog.
The Analog menu appears (see
Figure 6-13
).
2. From the Analog menu, select the port for the tone injection, and then select
Inject Tone Test.
The Inject Tone Test menu appears (see
Figure 6-14
).
3. Configure the desired parameters, according to
Table 6-9
.
4. Select Activate, then select Yes.
5. Repeat the procedure for all timeslots that you intend to test.
You can display information on all tests running at a time by selecting Display
Active Tests from the Diagnostics menu.
Analog
1. Inject Tone Test>
2. Remote Loop Test>
Figure 6-13. Analog Menu