Chapter 4 Configuration Installation and Operation Manual
4-2 Configuring for Management Vmux-210 Ver. 1.1
Table 4-1. System Parameters
Parameter Description Possible Values/
Reference
Management Opens the Management menu See
Figure 4-2
Date & Time Opens the Date & Time menu See
Figure 4-68
Factory Default Resets Vmux-210 to factory default settings
Note: Select Without Management to clear
only bundles and voice ports.
All
Without
Management
Alarm Operations Opens the Alarm Operations menu See
Figure 4-69
Main Link Main link interface (uplink); all voice frames
exit the device through the main-link
Note: The device resets automatically (upon
update of the database) when this
parameter is modified.
Ethernet
Serial
E1/T1
Default: Ethernet
Router Enables the Router
Note: The device resets automatically (upon
update of the database) when this
parameter is modified.
Enable
Disable
Default: Disable
Ethernet Net/User
Connection
Type of connection between Ethernet ports
in Router mode
Notes:
This parameter is available only when the
router is enabled and the Main Link is
defined as E1/T1 or Serial.
When the Main Link is defined as
Ethernet and the Router is enabled, the
value is automatically set to Layer 3
Routing.
The device resets automatically (upon
update of the database) when this
parameter is modified.
Layer 2 Switching
Layer 3 Routing
Default: Layer 2
Switching
Reset Unit Resets Vmux-210