Chapter 5 Configuring Vmux-210 for a Typical Application Installation and Operation Manual
5-2 Configuring the Local Vmux-2100 Vmux-210 Ver. 1.1
5.2 Configuration Sequence
The recommended configuration procedure for this application includes the
following steps:
1. Configure the local Vmux-2100.
2. Configure the IP host parameters for both remote Vmux-210 units via an
ASCII terminal connection.
3. Install the two Vmux-210 units at their locations.
4. Configure one of the Vmux-210 units.
5. On the management station, save the configuration file (cnfg210.dat) of the
configured Vmux-210 unit. This is done by running a TFTP server application
on the management station.
6. Download the configuration file to the second Vmux-210 unit. This is done by
running a TFTP server application on the management station.
7. Modify the relevant parameters on the second Vmux-210 unit.
5.3 Configuring the Local Vmux-2100
This section provides only a summary of the parameters necessary for the voice
E1 configuration of the central Vmux-2100. See the appropriate sections of the
Vmux-2100 Installation and Operation Manual
for more detailed instructions.
To configure the central Vmux-2100:
1. Assign the 172.17.15.11 IP address to the E1 group 1.
2. Add two bundles and configure them as follows:
Connect – Yes
Function – TDMoIP
Destination IP:
Bundle 1 – 172.17.15.20
Bundle 2 – 172.17.15.21
Destination Bundle – 1
Packetizing Interval – 30
Coder Rate – G723.1/6.4
Fax – Enable at 9.6 kbps.
3. Configure E1 parameters of the first external E1 bundle:
Connect – Yes
Frame – G.732S
Restoration – CCITT
Page view 137