Vmux-210 Ver. 1.1 Introduction 2-1
Chapter 2
Installation and Setup
2.1 Introduction
The Vmux-210 unit is designed for desktop or bench installation and is delivered
as a fully assembled unit. No provisions are made for bolting the unit to a
tabletop. For installation of one or two units in a 19” rack, refer to the
Rack
Mounting Kit for 19-inch Racks Guide
that comes with the rack mounting kit.
The following is a summary of the installation steps. These steps are described in
more detail later in this chapter.
To install Vmux-210:
1. Prepare the installation site in accordance with your application. See
Site
Requirements and Prerequisites
on page
2-2
.
2. Review the package contents, and verify that all items are present. See
Package Contents
on page
2-2
.
3. Connect the cables:
Connect the main link to the 10/100BaseT (NET Ethernet) port or the
E1/T1/Serial port.
Connect the LAN to the USER Ethernet port.
Connect an ASCII terminal or a PC running a terminal emulation software.
Connect power to the unit.
After installing the unit:
• See
Chapter 3
for the operating instructions.
• See
Chapter 4
for the detailed system configuration procedures using an
ASCII terminal connected to the Vmux-210 control port.
• If a problem is encountered, see
Chapter 6
and
Chapter 7
for testing and
diagnostic instructions.
Internal settings, adjustment, maintenance, and repairs may be performed only
by a skilled technician who is aware of the hazards involved.
Always observe standard safety precautions during installation, operation, and
maintenance of this product.
Warning