Installation and Operation Manual Chapter 3 Operation
Vmux-210 Ver. 1.1 Configuration and Management Alternatives 3-9
To initiate a control session:
1. Connect the terminal cable to the CONTROL connector on the Vmux-210 back
panel.
2. Connect the terminal cable to the serial port of the control terminal.
3. Turn the control terminal on.
4. Configure the terminal to the default communication parameters: one start
bit, eight data bits, no parity, one stop bit, no flow control, VT100 emulation.
5. Turn Vmux-210 on.
6. After Vmux-210 completes the boot sequence (approximately 50 seconds),
press <Enter> several times.
The rate is detected automatically.
Logging In
You have to enter a user name and password in order to start the Vmux-210
management software (see
Figure 3-2
).
USER NAME:
PASSWORD:
ESC - clear; & - exit
Figure 3-2. Password Request Screen
To enter the user name and password:
1. Type your user name, and press <Enter>.
2. Type your password (up to eight characters), and press <Enter>.
The Main Menu appears (see
Figure 3-3
).
Main Menu
1. Inventory[]
2. Configuration>
3. Monitoring>
4. Diagnostics>
5. File Utilities>
>
Please choose item <1 to 5>
@ - Db Update; # - Db Undo
ESC-prev.menu; !-main menu; &-exit
Figure 3-3. Main Menu