Installation and Operation Manual Chapter 4 Configuration
Vmux-210 Ver. 1.1 Configuring for Operation 4-9
Table 4-8. Serial Uplink Parameters
Parameter Description Possible Values/
Reference
Interface Type Physical interface type of the Serial port V35
X21
EIA-530
EIA-530-A
Default: V35
Connect Administrative status of the Serial port Yes
No
Default: No
Speed (N*64) Speed of the Serial port 1..32
Default: 1
Clock Mode Clock mode of the serial port DCE
DTE
Default: DTE
Control Signals Whether to ignore control signals
Note: This parameter is available only when
the Interface Type is defined as V35 and the
Clock Mode is defined as DTE.
Ignore
Obey
Default: Ignore
Fragmentation Maximum size (in bytes) of frames that are
not to be fragmented before mounting Serial
port; frames at are below this size are not
fragmented
200..1550
Default: 610
HDLC Mode Type of header added to HDLC frames Transparent HDLC
Cisco Bridged Eth
Default:
Transparent HDLC
Loop Detect Enables detection of loops in the TDM
network. When a loop is detected, a
corresponding alarm is recorded in the alarm
log, and all Ethernet frames being looped
back from the TDM uplink are blocked, and
prevented from being sent back to the
user's LAN. This mechanism prevents the
occurrence of undesired broadcast storms
and IP loops in the user’s LAN due to a loop
on the TDM network.
Enable
Disable
Default: Disable