Installation and Operation Manual Chapter 5 Configuring Vmux-210 for a Typical Application
Vmux-210 Ver. 1.1 Configuring Vmux-210 5-5
Configuring Analog Voice Parameters
To configure the analog voice parameters:
1. Display the Bundle Configuration menu, and add bundle 1 to the system
(Main Menu > Configuration > Bundles > Configure > Add Bundle).
2. Display the Edit Bundle menu, and configure the bundle 1 parameters to the
following values (Main Menu > Configuration > Bundles > Configure > Edit
Bundle):
Connect – Yes
Function – TDMoIP
Destination IP – 172.17.15.11
Destination Bundle – 1
Packetizing Interval – 30
Coder/Rate – G723.1A/6.4
Fax – Enable at 9.6 kbps.
3. Display the Signaling Parameters menu (Main Menu > Configuration > Bundles
> Configure > Edit Bundle > Signaling Parameters), and configure the ABCD
bits to represent the ON-HOOK/OFF-HOOK state according to the remote
PBX.
4. Display the Ports Distribution menu, and configure the voice timeslots
belonging to the first Vmux-2100 bundle (Main Menu > Configuration >
Bundles > Channel Distribution > Configure):
Update from Time Slot – 1
To Time Slot – 15
Type – Voice
Bundle – 1
Destination Port ID – 1
Destination Time Slot ID – 1
Update Time Slot
Update from Time Slot – 16
To Time Slot – 30
Type – Voice
Bundle – 1
Destination Port ID – 1
Destination Time Slot ID – 17.
Timeslot 16 on the remote E1 interface is reserved for signaling.