Chapter 5 Configuring Vmux-210 for a Typical Application Installation and Operation Manual
5-4 Configuring Vmux-210 Vmux-210 Ver. 1.1
Destination Time Slot ID – 16.
Now you can proceed with configuration of remote Vmux-210 units.
5.4 Configuring Vmux-210
Most of the configuration procedures are performed on one of the units, except
for defining IP parameters of the remote Vmux-210.
Configuration procedure is divided into two main stages:
Defining system parameters.
Setting analog voice parameters.
You must save the selected values by updating the Vmux-210 database. If the
database is not updated, Vmux-210 discards all the user settings when it is reset.
You can save selected values at any stage of the configuration procedure.
Configuring System Parameters
To configure the Vmux-210 system parameters:
1. Configure an ASCII terminal to:
One start bit
Eight data bits
No parity
One stop bit
No flow control
VT100 emulation.
2. Connect the terminal to the Vmux-210 CONTROL port.
3. Press <Enter> several times (to allow Vmux-210 to detect the rate).
4. Initiate the control session by entering the user name and password.
5. Display the Host IP menu and enter the IP address (172.17.15.20), its subnet
mask and default gateway values (Main Menu > Configuration > System >
Management > Host IP).
6. Repeat step 2 to step 4 for the second Vmux-210 unit, and assign the
172.17.15.21 IP address to it.
The rest of the configuration procedure refers to the first unit. Information
applicable to both units (or only to the second Vmux-210) is explicitly identified.