Installation and Operation Manual Chapter 4 Configuration
Vmux-210 Ver. 1.1 Configuring for Operation 4-11
T1 Parameters
1. Connect> (Yes)
2. Frame Type> (ESF)
3. Clock Mode> (LBT)
4. Interface Type> (DSU)
5. Restoration Time> (1 Second (Fast))
6. Idle Code[1 - ff]... (ff)
7. Line Code> (B8ZS)
8. Rx Sensitivity> (LOW (-15dB))
9. Tx Gain Level> (0 dBm)
10. Line Length> (0-133 Feet)
11. Fragmentation [200 - 1550]... (610)
12. HDLC Mode > (Transparent HDLC)
13. Loop Detect > (Disable)
Figure 4-11. T1 Parameters Menu
Table 4-11. T1 Parameters
Parameter Description Possible Values/
Reference
Connect Administrative status of the T1 port Yes
No
Default: No
Frame Type Frame type of the T1 port ESF
SF (D4)
Default: ESF
Clock Mode Clock mode of the T1 port Internal
LBT
LBT from Sublink
Default: LBT
Interface Type Interface type of the T1 port CSU
DSU
Default: CSU
Restoration Time Restoration time of the T1 port 1 Second (Fast)
10 Seconds
(62411)
Default: 1 Second
(Fast)
Comments to this Manuals