Page view 96
Installation and Operation Manual Chapter 4 Configuration
Vmux-210 Ver. 1.1 Configuring for Operation 4-29
Configuring a Bundle’s Signaling Parameters
To configure a bundle’s signaling parameters:
From the Main Menu, select Configuration > Bundles > Configure >
Edit Bundle > Signaling Parameters.
Signaling Parameters
1. Signaling Bits[]
2. Ringback> (Enable)
3. Reverse Polarity> (Disable)
4. Pulse Metering> (Enable)
5. Pulse Metering Frequency (khz)> (16)
6. Pulse Metering Duration (ms) [100 – 250] … (150)
Figure 4-30. Signaling Parameters Menu
Table 4-30. Signaling Parameters
Parameter Description Possible Values/
Reference
Signaling Bits Opens the Signaling Bits screen See
Figure 4-31
Ringback Enables remote ringback for this bundle Enable
Disable
Default: Enable
Reverse Polarity Enables reverse polarity synthesis for this
bundle
Note: Sanity check does not allow polarity
and metering on the same bundle.
Enable
Disable
Default: Disable
Pulse Metering Enables pulse metering synthesis for this
bundle
Note: Sanity check does not allow polarity
and metering on the same bundle.
Enable
Disable
Default: Disable
Pulse Metering
Frequency (kHz)
Frequency of synthesized pulse metering for
this bundle
Note: This parameter is available only when
Pulse Metering is enabled.
12
16
Default: 16
Pulse Metering
Duration (ms)
Duration of synthesized pulse metering for
this bundle
Note: This parameter is available only when
Pulse Metering is enabled.
100..250
Default: 150
When working opposite Vmux-110/FXO, Ringback should be disabled to allow
passing of CLID.