Installation and Operation Manual Quick Start Guide
Optimux-106 Ver. 6.1 Configuring the Optimux-106 3
3. Configuring the Optimux-106
Configuring IP Host Parameters
³ To define the Host IP parameters:
1. From the Management menu, select Host.
2. From the Host menu, perform the following:
Select IP Address to define the host IP address
Select IP Mask to define the host IP mask
Select Default Gateway to set the default gateway IP address.
The default gateway must be in the same subnet as the host.
Configuring Control Port Parameters
³ To configure the control port data rate:
1. From the Control Port menu (Configuration>System>Control Port), select
Baud Rate.
2. Select the terminal rate by typing the number corresponding to the desired
value, and then press <Enter>.
3. From the Control Port menu, select Security Timeout to set it to OFF or to 10
minutes.
4. From the Control Port menu, select Pop Alarm to set it to ON or to OFF.
Configuring the MNG-ETH port
³ To configure the MNG-ETH port:
1. From the Configuration menu select Physical Layer>Ethernet.
2. Select Device Number to set the device location (local or remote).
3. Select Port Number to set the Fast Ethernet port number to ETH-MNG.
4. Select Auto Negotiation to toggle between the Enabled and Disabled options.
5. Select Flow Control to toggle between the Enabled and Disabled options.
6. Select Alarms to mask or unmask the Fast Ethernet alarms. This option
identifies whether alarms triggered by this Ethernet port are masked or not.
When masked, these alarms are not trapped and are not recorded in the log
file.