Chapter 4 Configuration Installation and Operation Manual
4-12 Configuring Optimux-106 for Operation Optimux-106 Ver. 6.1
Configuring Redundancy
Configuring Local Redundancy
Optimux-106
Configuration>System>Redundancy>Local Redundancy
1. Force Link (LINK A)
2. Mode > (Auto)
>
Please select item <1 to 2>
ESC-Previous menu; !-Main Menu; &-Exit
Figure
4-16. Local Redundancy Menu
Table
4-11. Local Redundancy Parameters
Parameter Possible Values Description
Force Link Link A
Link B
Sets the active link.
Mode Auto When the selected Main Link (for example, Link A)
fails, Optimux-106 automatically switches over to
the backup Main Link (Link B, in this example). When
Link A recovers, the active link returns to Link A.
Manual When the selected Force Link fails, the system
switches to the backup link. The backup link remains
in use, even if the Force Link returns to service.
Off Turns off redundancy. When the selected Main Link
fails, Optimux-106 does not change over to the
backup Main Link.
You can set the mode for the remote device, which will then perform redundancy
according to the status of its links.
Configuring Remote Redundancy
Optimux-106
Configuration>System>Redundancy>Remote Redundancy
1. Force Link > (LINK A)
2. Mode > (Auto)
>
Please select item <1 to 2>
ESC-Previous menu; !-Main Menu; &-Exit
Figure
4-17. Remote Redundancy Menu
The parameters for configuring remote redundancy are the same as those for
configuring local redundancy. For more information, see
Table
4-11
.
Note