RAD Data comm Optimux-106 Specifications Page 44

  • Download
  • Add to my manuals
  • Print
  • Page
    / 110
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 43
Chapter 3 Operation Installation and Operation Manual
3-2 Indicators Optimux-106 Ver. 6.1
Figure
3-2. Optimux-106 Front Panel – Metal Enclosure
Table
3-1. Optimux-106 Indicators
LED Function Color Meaning
PWR Green Power supplies A and B are functioning correctly or PSA is good and PSB
is not installed or PSB is good and PSA is not installed
Red PSA exists but is faulty
Yellow
Off
PSB exists but is faulty
Power is Off
Link A Red
Yellow
Off
Signal loss or sync. loss detected
AIS detected (Optimux-106-T1 version only)
Normal operation – no alarm is detected, or power is Off
Link B Red
Yellow
Off
Signal loss or sync. loss detected
AIS detected (Optimux-106-T1 version only)
Normal operation – no alarm is detected, or power is Off
CH1 Yellow
Red
Off
AIS detected on T1 Ch1
Signal loss detected on T1 CH1
Normal oparation – no alarm is detected or power is Off
CH2 Yellow
Red
Off
AIS detected on T1 Ch2
Signal loss detected on T1 CH2
Normal oparation – no alarm is detected or power is Off
CH3 Yellow
Red
Off
AIS detected on T1 Ch3
Signal loss detected on T1 CH3
Normal oparation – no alarm is detected or power is Off
CH4 Yellow
Red
Off
AIS detected on T1 Ch4
Signal loss detected on T1 CH4
Normal oparation – no alarm is detected or power is Off
Page view 43