RAD Data comm MPW-1 Specifications Page 96

  • Download
  • Add to my manuals
  • Print
  • Page
    / 108
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 95
Chapter 4 Troubleshooting and Diagnostics Installation and Operation Manual
4-18 Troubleshooting MPW-1 MP-4100 Ver. 2.0
4.4 Troubleshooting
In case a problem occurs with one of the pseudowires carried by the MPW-1
module, check the displayed alarm messages and refer to
Section
4.3
and to the
Megaplex-4100 Installation and Operation Manual
for their interpretation.
If the problem is detected the first time the module is put into operation,
perform the following preliminary checks before proceeding:
Check for proper module installation and correct cable connections, in
accordance with the system installation plan.
Check the module configuration parameters in accordance with the specific
application requirements, as provided by the system administrator.
If the Megaplex-4100 nodal clock is to be locked to the clock recovered from
one of the pseudowires carried by the MPW-1 module, make sure a suitable
fallback clock source is configured and provides a good clock signal.
After collecting all the relevant information, perform the actions listed below until
the problem is corrected:
Make sure that no test has been activated on the corresponding MPW-1
internal DS1 port. Use the Megaplex-4100 management system to find the
active test or loopback, and deactivate it.
Activate the local loopback on the corresponding port timeslots that carry the
corresponding pseudowire. While the loop is connected, the user’s equipment
served by pseudowires configured on the corresponding port should receive
its own signal; if not, the problem is external. Check cable connections, and
any transmission equipment providing the link to the user’s equipment.
You can rapidly check the link to the remote unit by activating, at the remote
unit, the remote loopback on the corresponding timeslots of the remote
internal DS1 port. If the link operates OK, the local user’s equipment served
by pseudowires configured on the corresponding port should receive its own
signal.
If the test fails, there is a problem with the transmission through the
network, or with the MPW-1 modules:
Using the ping test to check IP connectivity to the destination IP address
of the relevant pseudowires. If ping fails, the problem is in the network
Repeat the test after carefully checking all the configuration parameters
of the module and its ports. If the problem persists, replace the module
and check again.