Page view 21
Chapter 1 Introduction Installation and Operation Manual
1-10 Functional Description MPW-1 MP-4100 Ver. 2.0
all of the 32 timeslots of the port are handled as a single data stream and
are transparently connected to another user-selected port. In the framed
mode, only the payload timeslots are transparently connected (31 timeslots
when connecting to another E1 port, 24 for connecting to a T1 port).
The CL module takes care of all the tasks necessary to enable the MPW-1 TDM
cross-connect matrix to perform the desired services in accordance with the
cross-connect mode selected for each port, in a way similar to the functions
performed by the cross-connect matrix of each I/O module. Therefore, all the
routing functions are actually performed on the CL module: the MPW-1 matrix
only handles the transfer of payload between the chassis bus side and the
internal DS1 ports of the module, in accordance with the instructions received
from the CL module.
The result is that when using the DS0 cross-connect mode, the following services
are available for the traffic flowing through the module ports:
Services related to TDM traffic:
Connection of timeslots from I/O or PDH ports of other modules installed
in the Megaplex-4100 to the desired MPW-1 internal DS1 port. When
signaling support is enabled for the corresponding DS1 port, the matrix
also routes the signaling information associated with each voice timeslot
in parallel with the timeslot data.
Bypassing timeslots among the MPW-1 internal DS1 ports, or among
ports (channels) located on other modules and the internal DS1 ports
located on the MPW-1 module.
Unidirectional routing of timeslots, and broadcasting from one timeslot to
multiple destinations.
In addition to payload routing, the TDM cross-connect matrix is also used to
activate local and remote loopbacks on selected timeslots of the MPW-1
internal DS1 ports.
Connection of management traffic, to enable inband management via a
selected timeslot.
As mentioned above, when using the DS1 cross-connect mode, the whole group
of timeslots intended for the corresponding DS1 port is handled as a single
stream. Thus, the source port must also use the DS1 cross-connect mode and the
same framing mode.
Internal DS1 Ports
The internal DS1 ports are logical ports that provide the linkage between the
packet processing subsystem and the TDM subsystem:
On the TDM side, a DS1 port serves as an endpoint for traffic from the TDM
and signaling buses. Each I/O or PDH port in the Megaplex-4100 that will use
pseudowires on MPW-1 must be assigned bandwidth (timeslots) on the
internal DS1 port, using the standard Megaplex-4100 timeslot assignment
procedures.
On the pseudowire side, a DS1 port serves as the collection point for
timeslots to be carried by each pseudowire. Thus, to carry traffic from a
specific TDM port by means of a pseudowire, it is necessary to assign the
same timeslots on the TDM side and on the pseudowire side. The pseudowire
Page view 21