IPmux-11 Ver. 2.00 Site Requirements and Prerequisites 2-1
Chapter 2
Installation and Setup
2.1 Introduction
This chapter describes installation and setup procedures for the IPmux-11 unit.
After installing the unit, refer to Chapter 3 for the operating instructions.
If a problem is encountered, refer to Chapter 6 for test and diagnostic instructions.
Internal settings, adjustment, maintenance, and repairs may be performed
only by a skilled technician who is aware of the hazards involved.
Always observe standard safety precautions during installation, operation, and
maintenance of this product.
2.2 Site Requirements and Prerequisites
The IPmux-11 device is intended for installation on desktop, 19-inch racks and
walls. All the connections are made at the rear panel. A hardware kit (RM-33-2) for
mounting one or two IPmux-11 units into a 19-inch rack is available from RAD.
Drilling template for wall installation is provided at the end of the manual.
AC-powered IPmux-11 units should be installed within 1.5m (5 ft) of an
easily-accessible grounded AC outlet capable of furnishing the voltage in
accordance with IPmux-11 nominal supply voltage.
DC-powered IPmux-11 units require a -48 VDC power source, which must be
adequately isolated from the main supply.
Allow at least 90 cm (36 in) of frontal clearance for operating and maintenance
accessibility. Allow at least 10 cm (4 in) clearance at the rear of the unit for signal
lines and interface cables.
The ambient operating temperature of IPmux-11 should be 0 to 50°C (32 to
122°F), at a relative humidity of up to 90%, non-condensing.