Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics
IPmux-11 Ver. 2.00 Handling Alarms 6-15
Configuring the Bundle Statistics Collection
You can set the interval for the bundle statistics collection, as well the statistics
threshold.
To configure the bundle statistic collection:
From the Event Log menu (
Figure 6-7), configure the following:
Update bundle connection events: 1 sec, 1 min
Bundle connection events threshold (a number of events that cause the
alarm to be initiated): 1100.
6.3 Handling Alarms
Masking Alarms
You can mask any IPmux-11 alarm to prevent it from being reported to the
management stations.
To mask alarms:
1. From the Management menu, select Alarm trap mask.
The Alarm Trap Mask menu appears (see
Figure 6-9).
2. From the Alarm Traps Mask menu, select Alarm ID to choose alarm that you
intend to mask:
alarmLOS
alarmLOF
alarmAIS
alarmRDI
alarmFEBE
alarmExtClk
bundleConnectionStatus.
List of the alarm traps can be displayed by typing H.
3. Select Trap Status to enable or disable masking of the selected alarm.
Configuration>System>Management>Alarm trap mask
Active alarm traps: > (-)
1. Alarm ID <use 'help'>[1 - 40] ... (39)
2. Trap status (Masked)
>
Please select item <1 to 2>
ESC-prev.menu; !-main menu; &-exit 1 Mngr/s
Figure 6-9. Alarm Trap Mask Menu