User's Manual Chapter 4 Configuring Typical Applications
RADview-SC/TDMoIP IPmux-11 Creating Circuits 4-21
5. Click on the Primary Circuit tab (Figure 4-22) and configure the following
parameters:
Line Type = Framed-CRC
TDM Bytes in Frame = 48
OAM Connectivity = Enabled (checked).
6. Select Central and Branch Sites.
Figure 4-22. Manual Circuit Dialog Box – Primary Circuit Tab