User's Manual Chapter 4 Configuring Typical Applications
RADview-SC/TDMoIP IPmux-11 Creating Circuits 4-9
4. Select the following parameters:
Transmit Clock Source = Loopback
Line Type = Framed-CRC.
5. Click <Set>.
Figure 4-8. IPmux-14 E1 Interface Parameters