User's Manual Chapter 3 Configuration Management
Vmux-210 Ver. 1.0 Additional Tasks 3-43
Advanced Voice Parameters
Figure 3-27. Advanced Voice Parameters Dialog Box
Table 3-26. Advanced Voice Parameters
Parameter Possible Values/Remarks
DTMF Detection Enables or disables DTMF (Dual Tone Multi Frequency) detectors for this bundle
Enable, Disable
Default: Disable
NLP Cutoff Level
(Amplitude)
The non-linear processor (NLP) cutoff level for this bundle
0..1023
Default: 512
Note: This parameter is used by the echo canceller. It defines the maximum
absolute linear PCM amplitude of the near-end signal that will cause the NLP
module to be active and to mute low level residual echo & noisy surroundings.
DTD ERL Ratio Cutoff
(Q3)
The Double Talk Detection (DTD) Echo Return Loss (ERL) cutoff level
0..96
Default: 15
Note: This parameter is used by the echo canceller when echo exists and there is
voice with low volume on the line, in order to determine whether the near-end is
talking or not. Echo Return Loss (ERL) is the power difference in dB between the
far-end signal and the echo returned.
[OK] Click <OK> to close the dialog box.
Reading (Uploading) the Agent Configuration
The Read command uploads the current Agent configuration to the Edit
configuration.
The Read command is only available when there is communication with the
Agent.