ASM-20
Installation and Operation Manual Chapter 4. Troubleshooting and Diagnostics
11/4/99 12:34 Bit Error Rate Tester (BERT) 4-3
PATT
Pressed
Pattern
Generator
Pattern
Tester
Error
XMT
RCV
ASM-20
Figure 4-1 BERT Using Loops
Alternatively, the complete link can be tested when using two ASM-20
modems or an external BERT. Figure 4-2 illustrates the two options for testing
a complete link:
Press the PATT push button of the local modem and check the ERR/RPF
LED. At the remote side check an external BERT.
Press the PATT push button of the local and remote modems and check
their ERR LEDs.
LOCAL ASM-20
PATT
Pressed
PATT
Pressed
Pattern
Generator
Pattern
Generator
Error
Error
XMT
RCV
Pattern
Tester
Pattern
Tester
REMOTE ASM-20
511
External
BERT
Figure 4-2 Two BERTs Operating End-to-End